view cartView Cart   Downloads  Tracking  Home
Enter Your Email for our Newsletter:
Cage/NCAGE Code: 3FNF0 | CCR Certified | Sales Support: 1-888-971-9888 or 310-517-9888

ICP DAS Data Communication

Same Day Shipping



      

  Shop by Protocol

I-7530FT
envelopeE-mail this Product
Product Reference & Support :
  • User's Manual
  • Quickstart
  • Cut Sheet
  • Wire
  • Pin Assignment
  • Block Diagram
  • Software
  • CE Certification
  • FCC Certification


  • Intelligent RS-232/CAN low speed fault tolerant converter
    Product Pricing:
    I-7530-FT: $319.00  add to cart
    Please Call 1-888-971-9888 for Volume and OEM discount pricing!
    Features

    PM-213xCAN (Controller Area Network) is a serial bus system especially suited to structure intelligent industry devices networks and build smart automatic control systems. The following figure shows the application architecture for I-7530/I-7530-FT modules. The PC can be the CAN host, monitor or HMI to access/control the CAN device through the CAN network by the I-7530/I-7530-FT Converters. The programmable RS-232 device (For example: I-8411/I-8431/I-8811/I-8831/W-8031/W-8331/W-8731 embedded controller) can use the serial port to connect to the CAN network via the I-7530/I-7530-FT modules. In order to use the CAN network with traditional RS-232 devices, we provide a way to achieve this purpose. The I-7530/I-7530-FT are designed to unleash the power of CAN bus via RS-232 communication method. It accurately converts messages between CAN and RS-232 networks. This module let you to communicate with CAN devices easily from any PC or devices with RS-232 interface.

    I-7530 application

    Moreover, we expand the functionalities of I-7530/I-7530-FT for some special application. In pair connection mode, I-7530/I-7530-FT can be used to connect PC with other RS-232 devices at the same time. The application architecture may be as follows.

    I-7530 application 2

    3000V isolation on CAN side (only I-7530) 
    The CAN port of I-7530 is an isolated with 3000V isolation. This isolation can protect the local RS-232 devices from the damage signal coming from CAN network. 

    Watchdog inside
    The watchdog is a hardware reset circuit to monitor the operation status. When working in harsh or noisy environment, the I-7530/I-7530-FT may shut down by the external signal. The circuit may let the I-7530/I-7530-FT to work continuously and never halt.

    Power and Error indicator display
    There are two indicators on the I-7530/I-7530-FT.The power indicator can help user to check whether the I-7530/I-7530-FT is standby or transmitting/receiving messages. The Error indicator will be turned on when some errors occur on the I-7530/I-7530-FT. 

    Applications

    • Control System • Building Automation • Factory Automation • Distributed data acquisition 
    I-7530 Applications

    Features

    • Compatible with CAN specification 2.0A and 2.0B
    • Fully compatible with ISO 11898-2 standard (for I-7530)
    • Fully compatible with ISO 11898-3 standard (low speed fault tolerance) (for I-7530-FT)
    • Support various bauds from 10K bps to 1M bps
    • Jumper for 120 Ω terminator resistor (for I-7530)
    • Software configurable CAN and RS-232 communication parameters
    • Power, data flow and error indicator for CAN and RS-232
    • Watchdog inside
    • Support transparent communication mode
    • 1000 frames in CAN received buffer and 900 frames in RS-232 received buffer

    Software Utility Features

    • CAN bus Baud rate configuration
    • CAN acceptance filter configuration
    • CAN 2.0A or 2.0B specific selection
    • RS-232 Baud rate and data bit setting
    • RS-232 responded selection
    • Easy test to transmit/receive can messages
    • Setting for I-7530 communication mode (normal mode or pair connection mode)

    CAN Monitor & Datalog Tool

    • It has a CAN message field which can display the receiving CAN messages in Decimal or HEX mode.
    • Can display the timestamp of each received CAN message.
    • Users can change the display mode, up-down, down-up or stop.
    • It can count the number of received CAN messages.
    • Data Log : It can save the CAN message as “ txt ” file.
    • Has CAN ID filter function.
    • Can send CAN message to CAN BUS according the defined interval time.

    CAN Monitor

    Virtual CAN

    There are various communication interfaces among the CAN devices like PCI CAN board, Ethernet series and RS-232 series CAN module. According to different purpose of users’ projects, the users maybe need to choice different CAN products. Because of this situation, the programmer should develop different communication program to handle different CAN device. For example, the user should develop “Socket Client” to communicate with I-7540. When using I-7530, the users need “UART” technique to communicate with it. Nowadays, ICP DAS develop the Virtual CAN technique. The Virtual CAN driver is the excellent tool for users. It transforms whole CAN devices into Virtual CAN port. And then it generates Virtual CAN port like “VxCAN 1” or “VxCAN 2”. The users could send and receive CAN message by appointing the Virtual CAN port number. The users don't need to care about what kind of CAN device which is used.

    Virtual CAN

    Performance Test

    The test is the performance which transfer 8 bytes data frame from CAN to RS232. (for I-7530)
    CAN setting
    Transfer frames
    Transfer time(ms)
    RS-232 setting
    Receive frames
    Receive time (ms)
    The max frames/sec
    Data<8 byes/frme
    RS232 command length
    2.0A 1Mbps
    1,000
    200
    115200,n,8,1
    1,000
    2954
    338
    >=338
    22 B
    2.0A 1Mbps
    1,000
    200
    115200,n,7,1
    1,000
    2775
    360
    >=360
    22 B
    2.0B 1Mbps
    1,000
    200
    115200,n,8,1
    1,000
    3580
    279
    >=279
    27 B
    2.0B 1Mbps
    1,000
    200
    115200,n,7,1
    1,000
    3337
    299
    >=299
    27 B

    The test is the performance which transfer 8 bytes data frame from RS232 to CAN. (for I-7530)
    CAN setting
    Transfer frames
    Transfer time (ms)
    RS-232 setting
    Receive frames
    Receive time (ms)
    The max frames/sec
    Data<8 byes/frame
    RS232 command length
    2.0A 1Mbps
    1,000,000
    2,612,243
    115200,n,8,1
    1,000,000
    2,612,243
    382
    >=382
    22 B
    2.0A 1Mbps
    1,000,000
    2,441,130
    115200,n,7,1
    1,000,000
    2,441,130
    409
    >=409
    22 B
    2.0B 1Mbps
    1,000,000
    3,142,043
    115200,n,8,1
    1,000,000
    3,142,043
    318
    >=318
    27 B
    2.0B 1Mbps
    1,000,000
    3,142,043
    115200,n,7,1
    1,000,000
    2,966,646
    337
    >=337
    27 B
    Specifications & Additional Information
    Item
    I-7530
    I-7530-FT
    CAN Interface
    Controller
    Microprocessor inside with 20MHz
    Transceiver
    NXP 82C250
    AMIS 41682
    Channel number
    1
    Connector
    9-pin male D-Sub (CAN_L, CAN_SHLD, CAN_H, N/A for others)
    Baud Rate (bps)
    10 k, 20 k, 50 k, 125 k, 250 k, 500 k, 800 k, 1 Mbps
    10 k, 20 k, 50 k, 125 kbps
    Isolation
    3000 VDC for DC-to-DC, 
    2500 Vrms for photo-couple
    NONE
    Terminator Resistor
    Selectable 120Ω terminator resistor by jumper
    1 kΩ for CAN_H and CAN_L
    Specification
    ISO-11898-2, CAN 2.0A and CAN 2.0B
    ISO-11898-3 (low speed fault tolerance), CAN 2.0A and CAN 2.0B
    Receive Buffer
    1000 data frames
    RS-232 Interface
    Connector
    9-pin female D-Sub (TxD, RxD, GND, N/A for others )
    Baud Rate (bps)
    110, 150, 300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200bps
    Data bit
    5, 6, 7, 8
    Stop bit
    1, 2
    Parity bit
    None, Even, Odd
    Receive Buffer
    900 data frames
    LED
    Round LED
    ON LED: Power and Data Flow; ERR LED: Error Status
    Power
    Protection
    Power reverse polarity protection, Over-voltage brown-out protection
    Power Consumption
    1 W
    Mechanism
    Installation
    DIN-Rail
    Dimensions
    118mm x 72mm x 33mm
    Environment
    Operating Temp.
    -25 ~ 75 ℃
    Storage Temp.
    -40 ~ 80 ℃
    Humidity
    5 ~ 95% RH, non-condensing

    Div Bottom
    © 2009 ICP DAS USA. All rights reserved.