view cartView Cart   Downloads  Tracking  Home
Enter Your Email for our Newsletter:
Cage/NCAGE Code: 3FNF0 | CCR Certified | Sales Support: 1-888-971-9888 or 310-517-9888

ICP DAS Data Communication

Same Day Shipping



      

  Shop by Protocol

GW-7433D
envelopeE-mail this Product
Product Reference & Support :
  • User's Manual
  • Quick Start Guide
  • Hardware
  • Wire Diagram
  • Cut Sheet
  • Firmware
  • Utility


  • Modbus TCP Server / RTU Slave to CANopen Master
    Product Pricing:
    GW-7433D: $529.00  add to cart
    Please Call 1-888-971-9888 for Volume and OEM discount pricing!
    Features
    System Application“Embedded Internet” and “Embedded Ethernet” are hot topics today. Ethernet protocol is standard for local area networks. Via Internet, connectivity is occurring everywhere, from home appliances to vending machines, to testing equipment, to UPS. Ethernet for networks in industrial area is appealing because the required cabling is already installed. The GW-7433D is a solution that provides a communication transformation between CANopen protocol and Modbus/TCP protocol. It solves a mission-critical problem: connecting an existed CANopen network with Ethernet-base master device as long as this master device supports Modbus/TCP protocol. It enables CANopen networks to be coupled together with the Internet/Ethernet, whereby remote monitoring and controlling is achieved.

    For CANopen networks, the GW-7433D is a CANopen master device. It supports PDO and SDO functions to communicate with slave devices. From the view of Modbus/TCP networks, GW-7433D plays a Modbus/TCP server role to receive the commands from Modbus/TCP client or to reply the information to Modbus/TCP client. We provide Utility software for users to configure the parameters of CANopen salves or GW-7433D. When GW-7433D boots up, it will collect the necessary information from all slaves which are predefined in the GW-7433D by using Utility. The following figure shows the application architecture for the GW-7433D.

    Features

    • Programmable standard CANopen baud, such as 10Kbps, 20Kbps, 50Kbps, 125Kbps, 250Kbps, 500Kbps, 800Kbps and 1Mbps.
    • Support maximum 50 TxPDO, 50 RxPDO, 15 SDO to SDO server.
    • Support communication object: TxPDO, RxPDO, and server SDO.
    • Support on-line configure CANopen slaves.
    • Communicate with CANopen slaves automatically when GW-7433D boots up.
    • Allow 5 Modbus/TCP masters to access GW-7433D simultaneously.
    • CANopen Version: DS301 V4,01 .
    • Device Profile: DSP-401 v2.0 .

    Applications

    • Control Systems
    • Building Automation
    • Factory Automation
    • Distributed data acquisition

    GW-7433 Applications

    Utility

    • Add/remove CANopen slaves via Ethernet
    • Online getting and setting the CANopen slaves configurations via Ethernet
    • Get/Set Modbus/TCP input/output memory address
    • Display CANopen I/O mapping table
    • Configure the parameters of Ethernet and CAN bus

    Modbus TCP

    How Do I Use the Gateway?

    1. Select proper CANopen slaves for users’ application.
    2. Use the GW-7433D Utility to link the GW-7433D Module via Ethernet.
    3. Set the IO parameters of CANopen slave devices into GW-7433D by GW-7433D Utility.
    4. The GW-7433D module will initialize automatically and implement the GW-7433D in your Modbus/TCP network.

      Selection Guide

    Modbus TCP and RTU Commands Support

    Modbus TCP Command Support
    Code
    Name
    Description
    01(0x01) Read Coil Status Read the ON/OFF status of discrete outputs in the slave
    02(0x02) Read Input Status Read the ON/OFF status of discrete inputs in the slave
    03(0x03) Read Holding Registers Read the binary contents of holding registers in the slaves
    04(0x04) Read Input Registers Read the binary contents of input registers in the slaves
    05(0x05) Force Single Coils Forces one coil in a sequence of coils to either ON or OFF
    06(0x06) Preset Single Register Preset an integer value into a single register.
    15(0x0F) Force Multi Coils Forces each coil in a sequence of coils to either ON or OFF
    16(0x10) Preset Multi Registers Preset value into a sequence of holding registers
    Specifications & Additional Information
    GW-7433D
    CPU RDC 80186-80 Embedded CPU, or compatible
    Flash 512K bytes
    SRAM 512K bytes
    EERROM 16K bytes
    Ethernet port 10/100 Base-T
    Real Time Clock Year-2000 compliance; seconds, minutes, hours, date of the month, year, valid up from 1980 to 2079
    CAN Signal Support CAN_H, CAN_L
    Connecter 5-pin screw terminal connecter
    Power Consumption 3W
    COM1 N/A
    COM2 N/A
    COM Speed N/A
    CAN Controller Phillips SJA1000T CAN Controller
    CAN Transceiver Phillips 82C250 CAN Transceiver
    LED Directors MI, CI, ERR
    Display 7-segment LED: 5 digits
    Isolated 2500Vrms on CAN side
    Reauired Supply Voltage +10 ~ +30VDC
    Operating Temp -25°C to 75°C
    Storage Temp -40°C to 85°C
    Himidity 5 ~ 95%
    Dimensions 122 mm x 72 mm x 33 mm
    Related Products
    I-7232D
    CANopen / Modbus Gateway

    More Info
    I-8KCPS1
    CANopen Embedded Device with 1 I/O Expansion

    More Info
    NS-205
    Unmanaged 5-Port Industrial Ethernet Switch with Din Rail Mount - Operating Temperature -40 ~ +75 °C

    More Info
    I-7188E Converters
    Ethernet to Serial Port Converters. 1-8 Port Serial to Ethernet Converter / Intelligent Controllers

    More Info
    ET-7017
    8-channel Voltage & Current Analog Input with High Voltage Protection and 4-channel Isolated Output Data Acquisition Module, communicable over Ethernet and Modbus TCP Protocol

    More Info
    DIN-KA52F
    24V/1A Power Supply (Din-Rail Mount)

    More Info
    DP-660
    Dual Output Power Supply, 24V @ 2.5A & 5V @ 0.5A

    More Info

    Div Bottom
    © 2009 ICP DAS USA. All rights reserved.